• Mixing Help

    Started by Kurt Becker in pulsFOG: Dramm has a chemical use worksheet that can help with the calculations for your Autofog, PulsFOG and Coldfogger.   As always, follow the label first.  If the label has an area rate, go...
    11 1,499
  • Avid and Success

    Started by  in pulsFOG: Has anyone tried pulsfogging an Avid Success mix in their K10? Thanks
    2 120
  • Bacillus subtilis

    Started by Farmergrr in pulsFOG: Ο Bacillus subtilis μπορεί να χρησιμοποιηθεί ως πρότυπο Κ22 χωρίς να καταστραφεί από τη θερμοκρασία;
    1 73
  • Mainspring GNL in a Pulsefog

    Started by  in pulsFOG: I wanted to check if Mainspring GNL can be used in the Pulsefogger.  I have not seen anything on the label or online to verify. Thanks 
    1 114
  • K-22 Bio Questions

    Started by TimFecher in pulsFOG: Does anyone know the ID and OD of the black rubber tubing from the solution tanks to the injectors?  Should I use 90 octane gasoline or 95? On the barrel and in the manual, it says 95, but on...
    0 121
  • Upgrading a K-30 or K-30/20 to Dual Start

    Started by Kurt Becker in pulsFOG: The K-30 system can be upgraded to the NEW Dual Start system that uses an external battery to power a small compressor to start the PulsFOG. This procedure requires a bit of work, including drilling...
    0 102
  • foliar fertilizer

    Started by Farmergr in pulsFOG: liquid foliar fertilizer with trace elements can be used. amino acids and humus and organic fertilizers
    0 167
  • K-30/20 BIO Tanks Too Large for Smaller Volumes of Solution

    Started by Kurt Becker in pulsFOG: The K30/20 BIO has two 55 liter, square tanks. This can present an issue if you only want to apply two liters for a quick application. The solution will be difficult to dispense and the tank will...
    0 141
  • Visible Fog?

    Started by  in pulsFOG: Hello, we are using a chemical disinfectant but we are having trouble visually seeing the dispersion. Is there a fluid/chemical that can be applied with the disinfectant that would generate a more...
    2 171
  • Dosing nozzles K-50

    Started by Hector in pulsFOG: Hello,    We have one pulfog k-50 and we used this for apply Rhapsody (Basillus subtilis) in greenhouse.   What kind of nozzles do you recommend for this product? Best...
    0 100
  • Fogging azadirachtin products (Azaguard, Azadirec, Azatin, Ornazin)

    Started by Kurt Becker in pulsFOG: Some growers have asked about fogging azadirachtin products in the pulsFOG wondering if this requires the BIO units. Azadirachtin is not heat sensitive even though it can be naturally derived. It is...
    2 670
  • Good Aphid Spray

    Started by Smccoard in pulsFOG: Has anyone found a chemical that works well for aphids? I have been using the sprays I normally use with a hand sprayer and they haven't been working as well when I use them with the PulseFog. Thanks
    1 306
  • K-22 BIO FLOW RATE

    Started by JSPATTERSON in pulsFOG: I have worked and used a K-22 Bio for 4 years now, with variable degrees of success.  9/10ths of my problems I have chalked up to "user error" and a steep learning curve involving...
    2 157
  • Sulfur in the Puls-Fog

    Started by  in pulsFOG: Can we use micronized sulfur (or any other kind of sulfur) in the Puls-Fog?
    3 354
  • Copper sulfate in PulsFog

    Started by  in pulsFOG: Can copper sulfate, like phyton 27, be used in a pulsfog unit. If so, are application rates the same as in a foliar spray (in oz/acre), or should they be adjusted? Also, is it adequate to use a...
    1 158
  • Altus insecticide

    Started by jessy chesterton in pulsFOG: Has anyone thermal fogged altus insecticide? The label states DO NOT apply with handheld fogging or misting equipment - it does not say anything about thermal fog. Does anyone have some input? I...
    0 249
  • Fogging Cease and Milstop

    Started by Kurt Becker in pulsFOG: Dramm has coordinated with BioWorks to develop rates for both  Milstop  and  CEASE  in Low Volume Application equipment.  Both of these products are effective when fogged as...
    1 702
  • K-50 Shut Down Procedure - IMPORTANT

    Started by Kurt Becker in pulsFOG: The K-50 is a 275 hp thermal fogger. This type of machine can build a great deal of heat. During operation, the unit is cooled by fresh air being sucked into the combustion chamber over the barrel....
    0 107
  • Outdoor Fogging/Coverage & Efficacy

    Started by cdobler in pulsFOG: I recently purchased a Pulsfog Bio unit in order to conduct chemical application trials on leafy greens being grown outdoors.  We struggle with effective mildew and insect control due to the...
    1 155
  • Fogging Micro-Encapsulated chemistries in the PulsFOG

    Started by Kurt Becker in pulsFOG: We do not recommend applying micro-encapsulated products in the PulsFOG.  Because of the heat, it is possible to cause the capsules to become gummy and weak, causing them to stick together or...
    0 129
  • K-30-STD

    Started by  in pulsFOG: Hi! I have a k-30-std less than 10 hours of use on it.  My problem is that it goes through a whole tank of fuel around every 4 L of fogging mix.  I've played with the dials for around 2...
    6 213
  • Fogging organic crops with the PulsFOG

    Started by Kurt Becker in pulsFOG: With the ability to fog biorational pesticides and oxidizers with the PulsFOG, many organic growers are asking about using the machine for organic production. While the machine will work fine, the...
    0 324
  • Fogging BT (Bacillus Thuringensis)

    Started by Kurt Becker in pulsFOG: Often growers will question the use of BT in the standard PulsFOG. The assumption is that BT is alive and can be damaged by the heat of the standard units. Actually, BT is a toxin derived from the...
    0 340
  • TIP: Extra 10 liter tanks for Larger PulsFOG unit for smaller jobs.

    Started by Kurt Becker in pulsFOG: Often growers using the larger PulsFOG units such as the K-30/20 or K-30/20 BIO, will have smaller jobs to do.   While the 55 liter tank that these units come with are great for large areas, it...
    0 238
  • Std Nozzle for PulsFog K-10/O

    Started by  in pulsFOG: I have a newly acquired (used) PulsFog K-10/O, what is the stock nozzle that came with this unit? It currently has a #15, is that nozzle apropriate for cogging with a kerosene or mineral oil...
    0 224